•PR
interval- 120-200 ms
•Shows
how fast impulse travels from SA node to AV node.
•QT
INTERVAL
•<440
ms
•Shows
the duration for a complete ventricular systole and diastole.
| ECG report |
|---|
| Sinus rhythm with HR 68bpm.Left Ventricular Hypertrophy. |
|---|
| Notice the high R wave in V4/V5 overshooting AND CAUSING OVERLAP. |
|---|
| BP 150/90mmHg |
|---|
| The LVH Criteria.V1 + R in V5 or V6 ≥ 35 mm |
|---|
| other criteria used. |
|---|
CORNELL Voltage Criteria for LVH
(sensitivity = 22%, specificity = 95%)
| ||
|---|---|---|
1.Prepare electrocardiography machine for use
|
-Check ECG machine is in good working order connect it to power.
|
|
2. Prepare client for ECG procedure
|
-Reassure the patient the procedure is safe and the reason for it.
-Record client information
-Review client medical history
|
|
3. Attach ECG electrodes
|
-Maintain the client's privacy and dignity throughout procedure
-Complete preparation of client's skin for electrode placement as required
-Position the client correctly and comfortably and place electrodes in accordance with client's needs and current standards
-Attach leads correctly and double check lead placement
|
4. Produce an ECG tracing by printing
|
-Produce trace and check for interference, wandering baseline and amplitude
Make sure the waves are visible with no artifacts.
-Repeat trace if interference , increased amplitude or wandering baseline is identified
-Identify and action abnormal ECG patterns which require immediate medical attention
-Forward trace to cardiologist or requesting medical officer for reading
-Record test details according to department and organisation procedures
|
|
|
5. Complete ECG procedure. -Remove ECG leads and electrodes from client
-Refer the patient appropriately.
-Clean ECG leads and electrodes on completion of procedure in accordance with infection control guidelines OR
-Dispose of disposable ECG electrodes and other materials in accordance with waste management procedures.
-Store ECG machine as required making sure there is no entanglement or kinks of the leads.This will increase the longevity of your machine as well as of electrodes.
|